5-7 MW Turbines

Table Header Table Header
Power output (nameplate):
5.7MW
Footprint:
60ft x 10ft
Install Time:
4hrs (no crane)
Total transports:
1
Heat rate:
9800btu/kW-hr
Required inlet pressure
250psi

15-17 MW Turbines

Table Header Table Header
Power output (nameplate):
16.5MW
Footprint:
90ft x 20ft
Install Time:
12hrs (no crane)
Total transports:
5
Heat rate:
10,000btu/kW-hr
Required inlet pressure
500psi

30-35 MW Turbines

Mitsubishi FT8

Table Header Table Header
Power output (nameplate):
30MW
Footprint:
100ft x 40ft
Install Time:
24hrs (with crane)
Total transports:
9
Heat rate:
9100btu/kW-hr
Required inlet pressure
500psi

LCP TM2500 GEN6

Table Header Table Header
Power output (nameplate):
31.9MW
Footprint:
100ft x 40ft
Install Time:
48hrs (with crane)
Total transports:
5
Heat rate:
9100btu/kW-hr
Required inlet pressure
500psi

LCP TM2500 GEN8

Table Header Table Header
Power output (nameplate):
34.5MW
Footprint:
110ft x 40ft
Install Time:
48hrs (with crane)
Total transports:
3
Heat rate:
8709btu/kW-hr
Required inlet pressure
500psi
Table Header Table Header
Power output (nameplate):
35MW
Footprint:
110ft x 40ft
Install Time:
24hrs (no crane)
Total transports:
7
Heat rate:
9100btu/kW-hr
Required inlet pressure
500psi
Table Header Table Header
Power output (nameplate):
35MW
Footprint:
110ft x 40ft
Install Time:
24hrs (with crane)
Total transports:
7
Heat rate:
9100btu/kW-hr
Required inlet pressure
500psi
Table Header Table Header
Power output (nameplate):
35MW
Footprint:
110ft x 40ft
Install Time:
8hrs (no crane)
Total transports:
2
Heat rate:
8709btu/kW-hr
Required inlet pressure
500psi
Table Header Table Header
Power output (nameplate):
35MW
Power output (derated for ambient):
28MW West Texas
Footprint:
55ft x 95ft
Install Time:
24hrs
Total transports:
3
Heat rate:
8709btu/kW-hr
Required inlet pressure
500psi

50-100 MW Turbines

Table Header Table Header
Power output (nameplate):
56MW
Footprint:
68ft x 24ft x 22ft
Install Time:
14 weeks
Heat rate:
8647btu/kW-hr
Required inlet pressure
390-435psi

Fuel Management

Fuel required to run your power plant may not be available post op. Life Cycle Power can provide comprehensive fuel treatment and delivery services through our partners across the U.S.

Service & Operation Contracts

At Lifecycle Power, we offer comprehensive Service & Operation Contracts to ensure your power systems operate smoothly and efficiently. Our expert team provides regular maintenance, rapid response to any issues, and continuous monitoring to maximize performance and minimize downtime. Trust us to keep your power solutions running seamlessly, so you can focus on your core operations.

Turnkey Contract Power

With our Turnkey Contract Power solutions, you only pay for the power you use, not the equipment. We handle everything from installation to maintenance, delivering reliable and efficient power directly to your site. This hassle-free approach allows you to avoid upfront capital expenses and enjoy a steady, cost-effective power supply tailored to your needs.